CLT BBS processing manual

1 Binderholz Bausysteme GmbH PROCESSING MANUAL BINDERHOLZ CLT BBS

3 Binderholz Bausysteme GmbH TABLE OF CONTENTS Purpose............................................................................... 4 Target group. ..................................................................... 4 Work preparation - project planning............................ 5 Process of project planning............................................ 6 Presentation of plan......................................................... 7 Plan issuance. ................................................................... 8 Presentation of ceiling elements................................... 8 Presentation of wall elements. ...................................... 9 Axonometric projection + floor plan............................. 9 Edge processing CLT BBS............................................. 10 Drillholes........................................................................... 11 Cutouts.............................................................................. 12 Break-throughs............................................................... 13 Pocket milling | Limited rebate.................................... 14 Cutout angle < 90°. ........................................................ 14 Machining tolerances. ................................................... 15 Window and door openings.......................................... 16 Example | checklist for CLT BBS deliveries............... 17 Loading plans.................................................................. 18 Loading types | truck. .................................................... 19 Loading types | rail......................................................... 21 Loading types | containers............................................ 22 Manipulation | loading................................................... 23 Loading guidelines. ............................................................ 23 Consignment note - CMR. ............................................. 24 Example of delivery note............................................... 25 Manipulation | unloading. ............................................. 26 Unloading............................................................................ 26 Lifting anchor...................................................................... 26 Lifting slings. ...................................................................... 27 Lifting sling + pin. .............................................................. 27 Lifting slings for non-visible quality. .................................. 28 Lifting sling + pin. .............................................................. 28 Lifting slings double hole. .................................................. 29 Assy/T-lift screws............................................................... 29 Packages with premounted lifting slings........................... 29 Consequences of usage of wrong lifting systems by the customer.................................................................. 30 Manipulation | storage................................................... 31 Intermediate storage at the construction site.................... 31 Assembly | walls on ground floor................................ 32 Inspection of the slab......................................................... 32 Bituminous sealing against moisture................................. 32 Setting out the walls........................................................... 33 Installing of angles.............................................................. 33 Shimming............................................................................ 34 Foot threshold..................................................................... 34 Erection of first wall............................................................ 35 Erection of second wall. ..................................................... 36 Outer wall - inner wall........................................................ 37 Erection of remaining walls................................................ 37 Assembly | ceilings......................................................... 38 Application of sealing membrane. ..................................... 38 Mounting of the ceiling....................................................... 38 Second ceiling element...................................................... 39 Remaining ceiling elements............................................... 39 Execution detail: Longitudinal joint of element.................. 40 Execution detail: Longitudinal joint of element in the wall axes I jetty (e.g. balcony).................................. 40 Assembly | walls upper floor........................................ 41 Setting up the walls in the first upper floor. ...................... 41 Setting of angles................................................................. 41 Assembly | protection.................................................... 42 Weather protection............................................................. 42 Temporary construction time sealing................................. 42 Shell construction details. ..................................43 - 117 Safety at the construction sit.....................................118 Personal protection equipment........................................118 Fall protection...................................................................118

4 Binderholz Bausysteme GmbH Processing Manual binderholz CLT BBS PURPOSE binderholz provides this Processing Manual to assist in planning the proper handling and installation of binderholz CLT BBS. The informations in this manual is not project-specific and might not be relevant to the conditions of your project. This manual does not replace the advice of project design and construction professionals. TARGET GROUP This processing manual is intended for direct processors of binderholz CLT BBS.

5 Binderholz Bausysteme GmbH WORK PREPARATION - PROJECT PLANNING Interfaces from the drawing program Cadwork - Import | Export Processable file formats Import Export Cadwork 3D IFC SAT DXF IFC ACIS BTL RHINO STEP STEP RVT IGES SEMA Viewer Dietrichs HSB DXF DWG PDF With client plans or models as a basis, the binderholz planning department (AV_Projektierung) prepares mass timber for fabrication using CADWork. CADWork is 3D/CAM software for the timber construction industry. The table below shows the file formats we can import and export. The time need for binderholz to process mass timber for fabrication varies depending on the completeness and quality of the client design files provided to us.

6 Binderholz Bausysteme GmbH PROCESS OF PROJECT PLANNING Customer inquiry Clarification of need with Sales Dept. Internal processing Work preperation Project planning Consultation, if needed, and clarification of details Binderholz issues model, plans and parts list for client review Release by customer + clarification of logistics (final delivery details) OR amendment Production Dispatch

7 Binderholz Bausysteme GmbH PLAN PRESENTATION CLT BBS Qualities AB - Residential visible BC - Industrial visible C - Non-visible Wood types Spruce (F), Pine (K), Mixed conifers (NH) Top layer ESP - Prefabricated single-layer panel EKG - Fingerjointed lamellas Examples F-AB_ESP - Residential visible quality, top layer spruce, single-layer panel F-BC_EKG - Non-visible, coniferous wood, with individual finger joints Formats System-format panel - CLT BBS 125|120|4ft CLT BBS XL - Large format panel DL = Top layer longitudinal DQ = Top layer transverse Glulam GLT Setup combined (c), homogenous (h) Strength classes GL24, GL28, GL30, GL32 Qualities SI (visible quality), NSI (non-visible quality) Wood types Spruce (FI), Larch (LA) Example BSH GL24c NSI FI (glulam GL24 combined non-visible quality spruce) Presentation of plan The hatching in the cross-section indicates the direction of the lamellas.

8 Binderholz Bausysteme GmbH PLAN ISSUANCE Dimensions: All dimensions in the plans are given in millimeters [mm] and angles in degrees [°]. Overview drawing (OD): Representation of several components of an entire wall or ceiling or a section of a wall or ceiling. Used for plan checking and plan approval by the customer. Individual part drawing (IPD): The IPD shows a single component only. Two sections are provided for each component. For panels with a visible surface (AB, BC), the facing side is the visible side. The individual part drawing is a manufacturing drawing for production and is not primarily intended for customer control or plan approval. Attributes such as coating, corner design, and lifting system are listed on the IPD. View side: Surface of the component shown in plan or elevation. The red triangles at the bottom and right edge of the plan indicate the facing side in the section views. View side In the overview drawing (OD), the ceiling section is viewed from above. With one-sided visual quality, the view side is the non-visible side. The hatching of the sections is a purely schematic representation of the CLT BBS. View side In the individual part drawing (IPD), the ceiling element is viewed from below. For single-sided visible quality, the view side is the visible side. The hatching of the sections is a purely schematic representation of the CLT BBS. Non-visible elements Non-visible elements One-sided visible elements One-sided visible elements Overview drawing (OD) Individual part drawing (IPD) REPRESENTATION OF CEILING ELEMENTS View side Plan = Non-visible quality View side Plan = Non-visible quality View side Plan = Non-visible quality View side plan = Visible quality

9 Binderholz Bausysteme GmbH REPRESENTATION OF WALL ELEMENTS AXONOMETRY (AXO) + FLOOR PLAN Overview drawing (OD) Individual part drawing (IPD) Axonometry Floor plan View side In the overview drawing (OD), the view side is indicated at the bottom right by the red arrows. For single-sided visible walls, the visible side is always the view side. The hatching of the sections is a purely schematic representation of the CLT BBS. View side In the individual part drawing (IPD), the view side is indicated in the floor plan at the bottom right by red arrows. For single-sided visible walls, the visible side is always the view side. In addition, the red triangles indicate the view side (in relation to the sections). The hatching of the sections is a purely schematic representation of the CLT BBS.

10 Binderholz Bausysteme GmbH EDGE PROCESSING CLT BBS CLT BBS 125 | BBS 120 | BBS 4ft Non visible: at full component width, the longitudinal edges parallel to the grain are chamfered Visible: All edges parallel to grain (incl. cut-to-size edges) are chamfered. Edges created by machining remain sharp-edged. CLT BBS XL The the fiber-parallel outer edges of the BBS XL visible components are chamfered on the visible side (DL and DQ). Non-visible components are not chamfered.

11 Binderholz Bausysteme GmbH PRESENTATION OF DRILLHOLES Axis for fasteners (VBA) The diameters for fasteners are not labelled. The exact dimension can be found in the 3D model. Drillholes on the End Face (Ø 28 mm) - Only available in CLT BBS XL - Length max. 1300 mm - Manual machining Drilling position deviation: < 800 mm drilling length: up to 15 mm > 800 mm drilling length: up to 20 mm - Minimum distance between drill holes > 69 mm *Applies to all continuous machining operations on the plate edge. Drillholes on the top surface Green drillhole Drillhole extends through the entire strength of the component Red drillhole Drillhole on the viewed side, does NOT extend through the entire strength of the component Dashed drillhole Drillhole on the rear side, does NOT extend through the entire strength of the component Edge distance of individual drill holes: ≤ 100 mm diameter: Edge distance min. 3 cm > 100 mm diameter: Edge distance min. 6 cm Series of multiple drill holes*: Distance to the edge of the panel: min. 6 cm Risk of breakage cannot be completely ruled out Single hole Series of holes

12 Binderholz Bausysteme GmbH PRESENTATION OF CUTOUTS Cutout at 90° to the board surface Non-visible area Cutouts ≥ 100 mm: Corners are overcut Cutouts < 100 mm: Residual radius between 15-20 mm remains Visible area Cutout bevelled to the board surface Non-visible area Visible area Cutouts ≥ 200 mm: Corners are finished with sharp edges Cutouts < 200 mm: A residual radius of between 15 and 20 mm remains Cutouts ≥ 100 mm: Corners are overcut Cutouts < 100 mm: Residual radius between 15-20 mm remains Cutouts ≥ 200 mm: Corners are finished with sharp edges Cutouts < 200 mm: A residual radius of between 15 and 20 mm remains The red line shows the cut-out as drawn in the plans. The images show the actual machining.

13 Binderholz Bausysteme GmbH Visible area Corners are milled in the visible area. The remaining radius depends on the diameter of the milling cutter which in turn depends on the depth the of processing. Remaining radius of 15 - 40 mm PRESENTATION OF BREAK-THROUGHS Non-visible area Execution 1 Execution 2 Corners are overcut Cutout is smaller than 200 x 200 mm, but larger than 100 x 100 mm The remaining radius depends on the diameter of the milling cutter which in turn depends on the depth the of processing. Remaining radius of 15 - 40 mm The red line shows the cut-out as drawn in the plans. The images show the actual machining.

14 Binderholz Bausysteme GmbH POCKET MILLING | LIMITED REBATE Non-visible area Visible area PRESENTATION OF CUT-OUTS WITH ANGLES OF < 90° (ACUTE ANGLES) Non-visible area Visible area The red line shows the cut-out as drawn in the plans. The images show the actual machining. Residual radius remains The residual radius depends on the milling cutter diameter, which in turn depends on the depth of machining. Residual radius of 15 - 40 mm Residual radius remains The residual radius depends on the milling cutter diameter, which in turn depends on the depth of machining. Residual radius of 15 - 40 mm Pocket milling Pocket milling Limited rebate Limited rebate

15 Binderholz Bausysteme GmbH MACHINING TOLERANCES Openings Position ± 2 mm Dimension ± 2 mm Drillholes (Ø 12 - 30 mm in 2 mm increments*) Position ± 2 mm Depth in limited drillings ± 2 mm Millings Position ± 2 mm Dimension ± 2 mm Depth ± 2 mm Slots Position ± 2 mm Dimension ± 2 mm Slot width < 20mm Dimensions of building elements Length ± 2 mm Width ± 2 mm Thickness ± 1 mm Bevel cuts Position ± 2 mm Length ± 2 mm *Drillholes not listed are milled. The tolerances for milling apply.

16 Binderholz Bausysteme GmbH Reworking of milling radii for window and door openings At the customer‘s request, the milling radii in the corners of openings (dimensions > 200 x 200 mm), can be reworked in the factory to 90° corners. WINDOW AND DOOR OPENINGS On customer request Include rest element Corner design Opening detail Panel thickness 60 - 280 mm Opening size min. 200 x 200 mm V3 must be specified when ordering Element delivered with cut-out attached for removal on site Standard strip width: 150 mm Load bearing Standard No strips Strips for stability Corner design Opening detail Panel thickness 60 - 280 mm Opening size min. 200 x 200 mm In case of increased risk of breakage, a transport strip is necessary for improved stability Transport strip must be removed on site Number of strips depends on the remaining cross-section Load bearing V2 V3

17 Binderholz Bausysteme GmbH Customer’s information on unloading, accessways and assembly sequence. EXAMPLE | CHECKLIST FOR CLT BBS DELIVERIES

18 Binderholz Bausysteme GmbH LOADING PLANS • binderholz creates individual 3D loading plans for all transports, taking into account the customer‘s desired delivery and assembly sequence. Precise transport planning ensures smooth handling during unloading. • Different modes of transport, such as truck, rail, or container, are taken into account. • binderholz endeavors to comply with customer specifications as far as possible. However, legal requirements and load securing regulations may lead to deviations from customer requirements. • Scanning or clicking on the QR code on the binderholz package list opens the link to the online 3D viewer. In this viewer, it is possible to mark individual components in the 3D building model and thus identify the exact position of the packages or components on the means of transport . • Targeted optimization of the cargo space can reduce freight costs and thus reduce overall costs. Example of a 2D loading plan for truck shipments Example 3D viewer left hand side / linke Seite right hand side / rechte Seite back / hinten front / vorne Abmessungen (LBH): 12,9 x 2,92 x 2,64 m Auftraggeber: Bearbeiter: Datum: Hebehilfen: Planformat: Wurzbacher GmbH Andri Hofstädter 16.09.2025 DIN A3 Ladungssicherungsmittel: 7 x K120 Bauvorhaben: Telefonnummer: Auftragsnummer: LKW / Containe 275170_FFW_Wildenheid_Carolin_Klappacher 275170 1 Laderaum: E-Mail: Pakete: Bauteile: Netto-Gewicht: Offen Sondertransport ohne Begleitung andri.hofstaedter@binderholz.com 11 30 24.091 kg

19 Binderholz Bausysteme GmbH Standard open semitrailer • Fast loading and unloading • More loading volume possible TYPES OF LOADING | TRUCK Enclosed truck • If the dimensions of the CLT BBS elements permit it, delivery can be provided in enclosed trucks • Weather protection

20 Binderholz Bausysteme GmbH Packages • Various format sizes such as CLT BBS 125|120|4ft & CLT BBS XL elements are wrapped separately • Boards of similar dimensions are wrapped together to form packages • Intermediate storage of these packages at the construction site is possible • The foil acts as UV and weather protection • Unloading is possible by forklift or crane • Transport is carried out on-the-flat (except in containers) Face to face stacked loading - no sticker boards • Available with CLT BBS XL only • Truckload wrapped as a single package • Observe weather conditions during unloading • Unloading by means of a crane Final packing configuration is subject to load-securing requirements in accordance to applicable road traffic regulations (StVO).

21 Binderholz Bausysteme GmbH • Suitable for long-distance transport • Environmentally friendly • Larger load volumes are possible • Enclosed railway waggon: additional weather protection TYPES OF LOADING | RAIL Open railway waggon Enclosed railway waggon

22 Binderholz Bausysteme GmbH • Overseas • Possible with CLT BBS XL and CLT BBS 125|120|4ft • Small load volumes are possible • The load is protected from the weather TYPES OF LOADING | CONTAINERS Interior dimensions depend on loading method Truck Type of transport max. width max. length Standard transport < 2,55 m < 13,60 m (with overhang in AT. DE: 15.10 m – precondition: not dividable goods) Special transport without escort 2,55 m - 3,00 m 13,60 m - 18,80 m Special transport with escort 3,01 m - 3,50 m 18,80 m - 21,00 m Standard semitrailer open 2,49 m - 2,55 m 13,40 m - 13, 60 m Mega trailer open 2,49 m - 2,55 m 13,30 m - 13,60 m Rigid truck with trailer 2,49 m - 2,55 m 6,00 m + 7,00 m Steered semitrailer 2,49 m - 2,55 m 12,00 m - 13,60 m Low-loader 2,49 m - 2,55 m 12,00 m - 13,60 m (7,00 m - 9,00 m load area lowered throughout) Inloader < 1,50 m 9,00 m - 9,50 m Tarp < 2,45 m < 13,60 m Container Type of transport max. width max. length Container 40 feet high cube < 2,33 m < 11,90 m Container 40 feet open top - in/out of gauge < 2,34 m < 11,90 m Rail Type of transport max. width max. length Railway wwaggon open < 2,64 m < 21 m Railway waggon closed < 2,84 m < 22 m

23 Binderholz Bausysteme GmbH MANIPULATION | LOADING Execution Transport always in a lying position. Exception: loading in containers Packages wrapped in foil Underlays with anti-slip mats are used between the layers CLT BBS 125|120|4ft Execution The whole shipment is, or the individual packages, are wrapped in foil Observe weather conditions when unloading Underlays with anti-slip mats are used between the layers CLT BBS XL The final sequence of loading the packages is subject to loading safety rules according to the general road traffic regulations (StVO). CAUTION! - The access road to the construction must be approved for a 40t truck - Check whether the truck can make the trip to the construction site (maneuverability and curve radius) Loading guideline

24 Binderholz Bausysteme GmbH CONSIGNMENT NOTE – CMR The consignment note is an agreement on the contract of carriage in international road freight transport (available for all countries accessible via truck, i.e., all EU countries + Morocco, Russia, Iran etc.) The signatures serve to record the transfer of risk between the parties in writing. To be completed by the haulier Signature of Binderholz Bausysteme Signature of the carrier Date and signature of customer

25 Binderholz Bausysteme GmbH EXAMPLE OF DELIVERY NOTE Zimmerei GmbH Musterstraße 7 Max Mustermann Musterstraße 1 A-1234 Musterdorf A-1234 Musterdorf Rechnungsempfänger Kunde Vertreter Ihre USt-ID-Nr. Unsere USt-ID-Nr. ATU62322711 ATU65952524 11559 5162 LIEFERSCHEIN vom 561607 14.01.21 Nr. rhs zu Auftrag Nr. 254747 254747 LT 01 Spedition Frächtername Lieferung: DAP (Incoterms 2020) A-1234 Musterdorf Bezeichnung Holz Qualität Länge Breite Stärke Stück Menge in BBS 1.250 100 1 10m² 8.000 Profil ohne Profilierung 10000 100% PEFC ZERTIFIZIERT Cert.Nr. HFA-COC-0211 Frachtkosten* 1 1 Kombinationslieferung BBS max. 2,50 m x 13,50 m (BxL), max. 10m³/Auftrag, Zeitfenster für die Anlieferung ca. 3 Tage Zwischensumme Gewicht in kg: 480 Gesamt m³: 1,000 Menge m²: 10 Gelieferte Waren bleiben bis zur Bezahlung unser Eigentum! Holz stammt aus Nutzungen, die den jeweiligen gesetzlichen Vorgaben entsprechen. Wenn nicht anders ausgewiesen, stammen alle Waren aus PEFC kontrollierten Quellen -- HFA–CoC–0211 --. Ausgenommen mit (*) markierte Positionen. Verkauf in Übereinstimmung mit den Anforderungen der europäischen Holzhandelsrichtlinie (EUTR) 995/2010. Ware übernommen Seite 1 / 1 Binderholz Bausysteme GmbH · Brettsperrholz · bbs@binderholz.com · www.binderholz.com Niederlassung Hallein: Solvay-Halvic-Straße 46 · A-5400 Hallein · fon +43 6245 70500-0 · fax +43 6245 70500-7001 Firmensitz: Zillertalstraße 39 · A-6263 Fügen · fon +43 5288 601 · fax +43 5288 601-121 · Eingetragen Landesgericht Innsbruck · FN 275228 y · UID-Nr.: ATU62322711 Muster

26 Binderholz Bausysteme GmbH MANIPULATION | UNLOADING Execution Short-term interim storage of wrapped packages is possible Unloading by crane or forklift Underlays with anti-slip mats are used between the layers Unloading NOTE - Apply according to manufacturer’s instructions and approval of the lifting anchor Lifting anchor Lifting anchor

27 Binderholz Bausysteme GmbH MANIPULATION | UNLOADING Lifting slings Lifting sling NOTE - Apply according to manufacturer`s instructions - Single-use lifting sling for 800 kg lifting load per anchor point if it is designed as a choke hitch Lifting slings + bolt/thorn Lifting sling with a thorn NOTE - Apply according to manufacturer`s instructions - Use: Lifting of ceiling and wall elements - Lifting load: 1000 kg per anchor point 800kg per lifting sling 2000 kg per lifting sling Assembly sling Anchor type Load capacity Choke hitch U-fold parallel 800kg 2000kg Lifting sling Thorn

28 Binderholz Bausysteme GmbH MANIPULATION | UNLOADING Lifting slings for non-visible quality Choke hitch per lifting sling 800 kg Folded over / parallel per lifting sling 2000 kg Lifting slings with + pin Applicable from a thickness of 80 mm: Top layer lengthwise from a 3-layer setup Top layer traverse from a 5-layer setup Non-visible side Visible side Per lifting sling: 1000 kg

29 Binderholz Bausysteme GmbH MANIPULATION | UNLOADING Lifting slings double hole Assy/T-lift screws Packages with premounted lifting slings - Facilitates faster unloading and immediate lifting of packages at the construction site

30 Binderholz Bausysteme GmbH MANIPULATION | UNLOADING Consequences of usage of wrong lifting systems by the customer CAUTION! - Grouting due to missing edge protector - Grouting due to too narrow lifting slings GROUTING

31 Binderholz Bausysteme GmbH MANIPULATION | STORAGE Intermediate storage at the construction site ≥ 200 mm Schutzfolie CAUTION! - Maintain at least 20 cm distance between the package and solid, dry ground - Make sure to cover up CLT BBS XL elements not wrapped in foil - Practice increased caution in case of visible quality - Make sure to cover rips in the foil with sticky tape Protective foil

32 Binderholz Bausysteme GmbH ASSEMBLY | WALLS GROUND FLOOR Inspection of the slab Execution Check floor plate together with the master builder (re-measure on site and check the height) Bituminous sealing against moisture Execution Bituminous sealing (scorching) on the finished floor plate (after the drying time) Lay bituminous sealing against humidity according to the manufacturer’s instructions - if appropriate, lay two layers (observe structural physics) LEGAL NOTE All presentations, explanations, dimensions and selected materials are only recommendations and examples provided by binderholz.

33 Binderholz Bausysteme GmbH ASSEMBLY | WALLS GROUND FLOOR Setting out the walls Execution Starting out from established reference axes - Tear open longitudinal axes - Determine the angle with a laser measuring device (cross-line laser) Draw lines with a chalk line CHALK LINE Installing of angles Execution Fasten angle bracket on the marked line Maintain angle distance as required by statics LEGAL NOTE All presentations, explanations, dimensions and selected materials are only recommendations and examples provided by binderholz.

34 Binderholz Bausysteme GmbH ASSEMBLY | WALLS GROUND FLOOR Shimming Execution Shimming - adjust to the height and fixate every 1 m or 0.8 m Apply sufficiently thick layer of expansive mortar between shimmings along the full width of the wall and exceeding the length on the sides Foot thresholds Options Threshold preassembled by wood construction company Mounting of threshold at the construction site Larch wood threshold and sealing against ascending humidity LEGAL NOTE All presentations, explanations, dimensions and selected materials are only recommendations and examples provided by binderholz.

35 Binderholz Bausysteme GmbH ASSEMBLY | WALLS GROUND FLOOR Erection of first wall Execution Set the first wall, adjust to position and ensure true balance Screw on with the pegged angle brackets at the footpoint Fasten with the assembly supports (distance ca. 3 m) A fter that, disattach from the lifting equipment Practice increased caution with visible quality Mounting support Sealing tape LEGAL NOTE All presentations, explanations, dimensions and selected materials are only recommendations and examples provided by binderholz.

36 Binderholz Bausysteme GmbH ASSEMBLY | WALLS GROUND FLOOR Erection of second wall Execution Set up the second wall transverse to the first wall, to build a solid corner Establish true balance Screw on with the pegged angle brackets at the footpoint Screw the corner connection together Assembly support Screwed-on corner connection LEGAL NOTE All presentations, explanations, dimensions and selected materials are only recommendations and examples provided by binderholz.

37 Binderholz Bausysteme GmbH ASSEMBLY | WALLS GROUND FLOOR Outer wall - inner wall Execution Screw together outer wall with inner wall In case of a blunt joint or tongue & groove joint, insert sealing tape Erection of remaining walls Execution Set up the remaining walls Longitudinal connections should be screwed together using a connection board LEGAL NOTE All presentations, explanations, dimensions and selected materials are only recommendations and examples provided by binderholz.

38 Binderholz Bausysteme GmbH ASSEMBLY | CEILINGS Application of sealing tape Execution Attach sealing tape to the narrow sides (faces) of already standing walls Use selfadhesive tapes Avoid fastening them with clamps for reasons of noise protection The sealing plane must be from wall to wall Mounting of the ceiling Execution Place first ceiling element on the already standing walls Screw the ceiling elements onto the walls Mounting a ceiling with a magazine screwdriver LEGAL NOTE All presentations, explanations, dimensions and selected materials are only recommendations and examples provided by binderholz. © Getzner

39 Binderholz Bausysteme GmbH ASSEMBLY | CEILINGS Second ceiling element Execution Place second ceiling element and pull it towards the first ceiling element with several beam pulls Screw the ceiling elements together with the walls Connect the longitudinal joint of the elements with a connection board Remaining ceiling elements Execution Connect as with the previous ceiling elements Create fall protection for ceiling notches After setting up the remaining ceiling elements, apply sealing (flame cardboard) (apply according to manufacturer’s instructions) Fall protection LEGAL NOTE All presentations, explanations, dimensions and selected materials are only recommendations and examples provided by binderholz.

40 Binderholz Bausysteme GmbH ASSEMBLY | CEILINGS Execution detail of longitudinal joint of elements Execution If necessary, balance out the ceiling element from underneath Raise/lower with an assembly support before screwing the ceiling elements crosswise and screwing on the cover board Execution detail: Longitudinal joint of elements in the wall axes I jetty (e.g. balcony) Execution Sealing of the longitudinal element connections Noise protection in the interior area Creation of the airtight plane for the outside area

41 Binderholz Bausysteme GmbH ASSEMBLY | WALLS UPPER FLOOR Setting up the walls on the first upper floor Execution Starting out from the established reference axes - Tear up the longitudinal axes - Place angles to measure, using a laser measuring device (cross-line laser) Add chalk lines CHALK LINE Setting of angles Execution Attach angle pieces on the predrawn line Maintain angle distance as required by statics These are binderholz suggestions, hints, examples

42 Binderholz Bausysteme GmbH ASSEMBLY | PROTECTION Weather protection Execution CLT BBS may get wet during the construction phase, but avoid waterlogging Before mounting further layers (e.g. ceiling extension, roof structures), make sure wood moisture is reduced to a maximum of 18% (check with a wood moisture measuring device) Cover narrow areas (end grain) during the construction phase (use binderholz foil from the packages), install windows as fast as possible Caution with surfaces in visible quality: avoid optical defects caused by water stains and dirt pollution Temporary construction time sealing On request, a full-surface temporary construction time sealing can be applied on our CLT BBS elements at the factory. This can be temporarily used during the construction time for up to 4 weeks on ceilings and roofs and can be exposed to the weather (including driving rain and UV light). The processing instructions of the manufacturer of the sealing membrane as well as the binderholz instructions on the temporary construction time sealing, must be observed at any time. For further details, please ask our sales representatives. These are binderholz suggestions, hints, examples © SIGA © SIGA

43 Binderholz Bausysteme GmbH INDEX OF SHELL CONSTRUCTION DETAILS Shell construction details | symbols 44 Foundation - CLT BBS outer wall 46 Foundation - CLT BBS inner wall 50 CLT BBS outer wall - CLT BBS outer wall 52 CLT BBS wall - CLT BBS wall 54 CLT BBS outer wall - CLT BBS inner wall 59 CLT BBS inner wall - CLT BBS inner wall 60 CLT BBS outer wall - CLT BBS ceiling 61 CLT BBS inner wall - CLT BBS ceiling 66 CLT BBS ceiling/roof - CLT BBS ceiling/roof 67 CLT BBS outer wall - CLT BBS roof 71 Rafter solid wood - CLT BBS outer wall 73 Ridge 77 Attika as coating - CLT BBS flat roof 81 BSH girder - CLT BBS outer wall 82 BSH ceiling-level girder - CLT BBS ceiling 86 Steel girder - CLT BBS outer wall 87 Ceiling-level steel girder - CLT BBS ceiling 89 Steel support as suspender beam - CLT BBS ceiling 91 CLT BBS ceiling with a butt joint - CLT BBS inner wall 92 CLT BBS ceiling - wooden frame wall (outer wall) 93 CLT BBS ceiling - wooden frame wall (inner wall) 95 CLT BBS wall - wooden frame wall (outer wall) 96 CLT BBS wall - inserted CLT BBS ledge 98 Stairwell 102 CLT BBS ceiling - brickwall 105 CLT BBS ceiling - concrete wall 108 CLT BBS staircase 115

44 Binderholz Bausysteme GmbH SHELL CONSTRUCTION DETAILS | SYMBOLS Symbol Denomination Function Dimension (Examples) Concrete anchor or screw anchor For fastening on mineral substrate (concrete, stone) Ø 12 x 178 mm Ø 16 x 220 mm Fully threaded screw Selfdrilling screw for wood For the transmission of high tensile forces, e.g. in suspender beams Ø 8 x 140 mm Comb nail For fastening angle connectors, joist hangers, metal plates and for the execution of cross-type screw fittings Ø 4 x 60 mm Wood screw Selfdrilling partially threaded screw for wood Increase of the head pull-through value by means of using washers Ø 6 x 80 mm Ø 8 x 100 mm Ø 8 x 160 mm Washer head screw Selfdrilling partially threaded screw for wood Large screw head for high head pull-through values Ø 8 x 200 mm Ø 10 x 240 mm Ø 10 x 360 mm LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

45 Binderholz Bausysteme GmbH SHELL CONSTRUCTION DETAILS | SYMBOLS Symbol Denomination Function Dimension (Examples) Angle connector For fastening of wooden walls on substrate (wood, reinforced concrete) 100 x 100 mm Perforated metal plate For transmission of tensile forces 80 x 600 mm 3-layer panel For transmission of tensile forces Thickness 19 mm or 27 mm Tie rod Rod for tension connection between a wooden wall and substrate from reinforced concrete Height 540 mm Glue tape To create an airtight plane Recommended for wood-wood connections Width 60 mm Wall barrier from butyl Protection of the wood against ascending moisture Variable width Width 500 mm EPDM sealing tape Sealing to create an airtight plane Fasten with clamps Noise protection bearing Sealing to create an airtight plane Decouples in case of increased requirements for noise protection Colour division in different pressure strengths Application of different bearings depending on actual line load EPDM zigzag band Sealing to create an airtight plane Decouples in case of normal requirements for noise protection Depending on the construction object, specific calculation is recommended Glue Sealing to create an airtight plane PU glues, mounting glue Insulation Mineral wool, cellulose, EPS/XPS LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

46 Binderholz Bausysteme GmbH FOUNDATION - CLT BBS OUTER WALL Variant 1 - without threshold SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

47 Binderholz Bausysteme GmbH FOUNDATION - CLT BBS OUTER WALL Variant 2 - with threshold SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

48 Binderholz Bausysteme GmbH FOUNDATION - CLT BBS OUTER WALL Variant 3 - with concrete base and threshold SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

49 Binderholz Bausysteme GmbH FOUNDATION - CLT BBS OUTER WALL Variant 4 - with concrete base SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

50 Binderholz Bausysteme GmbH FOUNDATION - CLT BBS INNER WALL Variant 1 - without threshold SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

51 Binderholz Bausysteme GmbH FOUNDATION - CLT BBS INNER WALL Variant 2 - with threshold SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

52 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS OUTER WALL Variant 1 - with sealing tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

53 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS OUTER WALL Variant 2 - with glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

54 Binderholz Bausysteme GmbH CLT BBS WALL - CLT BBS WALL Variant 1 - rebate | sealing membrane SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

55 Binderholz Bausysteme GmbH CLT BBS WALL - CLT BBS WALL Variant 2 - tongue | sealing membrane SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

56 Binderholz Bausysteme GmbH CLT BBS WALL - CLT BBS WALL Variant 3 - rebate | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

57 Binderholz Bausysteme GmbH CLT BBS WALL - CLT BBS WALL Variant 4 - tongue | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

58 Binderholz Bausysteme GmbH CLT BBS WALL - CLT BBS WALL Variant 5 - stepped rebate | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

59 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS INNER WALL with sealing tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

60 Binderholz Bausysteme GmbH CLT BBS INNER WALL - CLT BBS INNER WALL with sealing tape | with threshold SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

61 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS CEILING Variant 1 - angle connection SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

62 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS CEILING Variant 2 - perforated metal plate connection SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

63 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS CEILING Variant 3 - solid wood plate SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

64 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS CEILING Variant 4 - continuous outer wall | bearing trimmer beam SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

65 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS CEILING Variant 5 - continuous outer wall | bearing T-square SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

66 Binderholz Bausysteme GmbH CLT BBS INNER WALL - CLT BBS CEILING SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

67 Binderholz Bausysteme GmbH CLT BBS CEILING/ROOF - CLT BBS CEILING/ROOF Variant 1 - rebate | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

68 Binderholz Bausysteme GmbH CLT BBS CEILING/ROOF - CLT BBS CEILING/ROOF Variant 2 - rebate | glue SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

69 Binderholz Bausysteme GmbH CLT BBS CEILING/ROOF - CLT BBS CEILING/ROOF Variant 3 - stepped rebate | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

70 Binderholz Bausysteme GmbH CLT BBS CEILING/ROOF - CEILING/ROOF Variant 4 - screwed crosswise | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

71 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS ROOF Variant 1 - sealing tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

72 Binderholz Bausysteme GmbH CLT BBS OUTER WALL - CLT BBS ROOF Variant 2 - glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

73 Binderholz Bausysteme GmbH SOLID WOOD RAFTER - CLT BBS OUTER WALL Variant 1 - without glue tape CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

74 Binderholz Bausysteme GmbH SOLID WOOD RAFTER - CLT BBS OUTER WALL Variant 2 - with glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

75 Binderholz Bausysteme GmbH SOLID WOOD RAFTER - CLT BBS OUTER WALL Variant 3 - rafter inserted | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

76 Binderholz Bausysteme GmbH SOLID WOOD RAFTER - CLT BBS OUTER WALL Variant 4 - rafter on BSH SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

77 Binderholz Bausysteme GmbH RIDGE Variant 1 - with stringer | sealing tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

78 Binderholz Bausysteme GmbH RIDGE Variant 2 - with stringer | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

79 Binderholz Bausysteme GmbH RIDGE Variant 3 - within stringer | sealing tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

80 Binderholz Bausysteme GmbH RIDGE Variant 4 - within stringer | glue tape SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

81 Binderholz Bausysteme GmbH ATTIKA AS SUSPENDER BEAM - CLT BBS FLAT ROOF SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

82 Binderholz Bausysteme GmbH GIRDER BSH - CLT BBS OUTER WALL Variant 1 - joist hanger CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

83 Binderholz Bausysteme GmbH GIRDER BSH - CLT BBS OUTER WALL Variant 2 - summer CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

84 Binderholz Bausysteme GmbH GIRDER BSH - CLT BBS OUTER WALL Variant 3 - push-in connection CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

85 Binderholz Bausysteme GmbH GIRDER BSH - CLT BBS OUTER WALL Variant 4 - glue tape SEALING CONSTRUCTION For protection of the BSH the BSH front can be completely covered with glue tape. LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

86 Binderholz Bausysteme GmbH CEILING-LEVEL BSH GIRDER - CLT BBS CEILING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

87 Binderholz Bausysteme GmbH STEEL GIRDER - CLT BBS OUTER WALL Variant 1 - with insulation SEALING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

88 Binderholz Bausysteme GmbH STEEL GIRDER - CLT BBS OUTER WALL Variant 2 - BSH support CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

89 Binderholz Bausysteme GmbH CEILING-LEVEL STEEL GIRDER - CLT BBS CEILING Variant 1 - with noise protection SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

90 Binderholz Bausysteme GmbH CEILING-LEVEL STEEL GIRDER - CLT BBS CEILING Variant 2 - CLT BBS milled SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

91 Binderholz Bausysteme GmbH STEEL SUPPORT AS SUSPENDER BEAM - CLT BBS CEILING CONSTRUCTION LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

92 Binderholz Bausysteme GmbH CLT BBS CEILING WITH BUTT JOINT - CLT BBS INNER WALL SEALING CONSTRUCTION increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

93 Binderholz Bausysteme GmbH SEALING CONSTRUCTION CLT BBS CEILING - WOODEN FRAME WALL (OUTER WALL) Variant 1 - without glue tape increased noise protection requirements lower noise protection requirements LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

94 Binderholz Bausysteme GmbH SEALING CONSTRUCTION CLT BBS CEILING - WOODEN FRAME WALL (OUTER WALL) Variant 2 - glue tape inside/outside LEGAL NOTE The presented dimensions (especially connecting means) and symbol images are to be understood as examples and do not replace subject specific or project-specific static and physical calculation.

RkJQdWJsaXNoZXIy NTQ5ODU5