Solid timber manual 2.0

ROOF 8 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.130  Sound insulation Rw [dB] 45  Ecology ∆OI3 123 A B D E C F G Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 20 Profiled sheeting — 7,800 A1 B 30 Wooden battens (30/50) 0.13 475 D C 80 Wooden counter battens 0.13 475 D D — Sheathing membrane (laminated; sd ≤ 0.12 m) — — E E 220 Mineral wool above-rafter insulation system, e.g. Isover Integra Basic 0.034 110 A1 F — Sealing sheet — — E G 100 CLT BBS, 5-layered 0.12 450 D Total 45 cm 86.66 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,265 18.3 0.584 Steep roof – solid timber construction, visual surface quality, rear ventilated: DA04 k

RkJQdWJsaXNoZXIy NTQ5ODU5