Solid timber manual 2.0

INTERIOR & PARTITION WALL 22 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 60 [kN/m] Heat insulation U [W/m²K] 0.283  Sound insulation Rw [dB] 52  Ecology ∆OI3 38 A B C D Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 C 10 Air space 0 — — D 100 CLT BBS, 5-layered 0.12 450 D Total 26 cm 91.20 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 727 -96.4 0.222 Partition wall – solid timber construction, visual surface quality: IW10 b