EXTERIOR WALL 26 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI i  o 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 60 [kN/m] Heat insulation U [W/m²K] 0.145  Sound insulation Rw [dB] 51  Ecology ∆OI3 90 A B C Exterior wall – solid timber construction: AW21 b Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 18 Plaster façade, e.g. webermin freestyle 0.45 1,600 A2 B 200 Mineral wool Isover Sillatherm WVP 1-035 0.034 125 A1 C 100 CLT BBS, 5-layered 0.12 450 D Total 31.80 cm 98.80 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 890 1.52 0.452