Solid timber manual 2.0

EXTERIOR WALL 13 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI i  o 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 60 [kN/m] Heat insulation U [W/m²K] 0.157  Sound insulation Rw [dB] 37  Ecology ∆OI3 49 A B C Exterior wall – solid timber construction, visual surface quality: AW13 b Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 7 Plaster facade, e.g. weberpas topdry 0.45 1,600 A2 B 220 Wood fibre insulation panel 0.04 140 E C 100 CLT BBS, 5-layered 0.12 450 D Total 32.70 cm 87 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 836 -62.1 0.236

RkJQdWJsaXNoZXIy NTQ5ODU5