Solid timber manual 2.0

EXTERIOR WALL 8 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI i  o 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 60 [kN/m] Heat insulation U [W/m²K] 0.146  Sound insulation Rw [dB] 45  Ecology ∆OI3 36 A B C E D F Exterior wall – solid timber construction, rear ventilated, visual surface quality: AW09 d Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 19 Wooden exterior wall cladding 0.15 525 D B 40 Wooden battens (40/60; e = 625) 0.13 475 D C — Sheathing membrane sd ≤ 0.3 m) — — E D 240 Construction hardwood (b ≥ 60; e = 625) 0.13 475 D E 240 Mineral wool, e.g. Isover Kontur FSP 1-035 0.034 24 A1 F 100 CLT BBS, 5-layered 0.12 450 D Total 39.90 cm 73.50 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 659 -82.7 0.209