Roof

ROOF SOLID TIMBER MANUAL 2.0

ROOF © Binderholz GmbH & Saint-Gobain Rigips Austria GesmbH 1st edition, May 2019 All information in this document reflects the latest state of development and has been prepared for you according to the best of knowledge and good faith. As we always strive to offer the best possible solutions for you, changes are reserved due to improvements in terms of application or production technology. Ensure yourself that you have the most recent edition of this document available. Printing errors cannot be ruled out. This publication is targeted at trained specialists. Any illustrations of executing activities contained in it are not understood to be any processing instructions, unless expressly marked as such. Renderings and sectional views of the individual assemblies are not depicted on scale; they serve merely as illustration. Our products and systems are aligned to each other. Their interaction has been confirmed by internal and external testing. All information is generally based on the exclusive use of our products. Unless described otherwise, the information does not permit any conclusions as to the combinability with third-party systems or exchangeability of individual parts by external products; to this end, no warranty or liability can be extended. Please also note that our business relationships are exclusively subject to our general terms of sale, delivery and payment (GTC) in the current version. You can receive our GTC on request or find them online at www.binderholz.com and www.rigips.com. We are looking forward to a good cooperation and wish you great success with all of our system solutions. Publisher Binderholz GmbH and Saint-Gobain Rigips Austria GesmbH Technical implementation Dipl.-Ing. (FH) Tim Sleik, Dipl.-Ing. Christian Kolbitsch and Dipl.-Ing. (FH) Jens Koch Graphic implementation Advertising Agency Goldfeder − Jasmin Brunner HOTLINES: Binderholz Bausysteme GmbH Saint-Gobain Rigips Austria GesmbH Tel. +43 6245 70500 Tel. +43 1 616 29 80-517 www.binderholz.com www.rigips.com

CONTENTS    Designation Fire resistance REI Thickness [cm] Sound insulation [dB] Heat insulation [W/m²K] Page DA01 b steep roof 30 49.20 54 0.131 4 DA01 k steep roof 60 56.45 62 0.110 5 DA02 k steep roof 30 45.00 52 0.130 6 DA02 l steep roof 60 52.25 59 0.109 7 DA04 k steep roof 30 45.00 45 0.130 8 DA04 l steep roof 60 52.25 52 0.109 9 DA05 a flat roof 30 32.25 39 0.138 10 DA05 c flat roof 90 41.25 43 0.114 11 DA05 f flat roof 60 39.50 43 0.115 12 DA05 g flat roof 30 33.50 39 0.137 13 DA06 a flat roof 30 37.25 55 0.136 14 DA06 c flat roof 90 46.25 61 0.113 15 DA06 f flat roof 60 44.50 61 0.114 16 DA06 g flat roof 30 38.50 55 0.135 17 DA07 a flat roof 60 34.25 39 0.135 18 DA08 a flat roof 60 39.25 55 0.133 19 DA09 a flat roof 30 32.25 48 0.151 20 DA09 b flat roof 30 33.50 48 0.150 21 DA09 c flat roof 60 39.50 54 0.124 22 DA09 d flat roof 90 41.25 54 0.123 23 DA10 a flat roof 30 37.25 56 0.149 24 DA10 b flat roof 30 38.50 56 0.148 25 DA10 c flat roof 60 44.50 62 0.123 26 DA10 d flat roof 90 46.25 62 0.121 27 DA11 a flat roof 60 34.25 48 0.147 28 DA12 a flat roof 60 39.25 56 0.146 29 ROOF

ROOF 4 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.131 Sound insulation Rw [dB] 54  Ecology ∆OI3 53 Steep roof – solid timber construction, visual surface quality, rear ventilated: DA01 b A B D E C F G Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Concrete roofing tiles — 2,100 A1 B 30 Wooden battens (30/50) 0.13 475 D C 50 Wooden counter battens (min 50 mm) 0.13 475 D D 22 Under-ceiling board, wood fibre insulation panel 0.05 250 E E 240 Wood fibre insulation panel 0.04 110 E F — Sealing sheet — — E G 100 CLT BBS, 5-layered 0.12 450 D Total 49.20 cm 136.18 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 909 -67.6 0.257

ROOF 5 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Steel roof – solid timber construction, rear ventilated: DA01 k Building physical and ecological rating Fire protection REI i  o 60 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.110 Sound insulation Rw [dB] 62  Ecology ∆OI3 59 A B D E C G F H I J Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Concrete roofing tiles — 2,100 A1 B 30 Wooden battens (30/50) 0.13 475 D C 50 Wooden counter battens (min 50 mm) 0.13 475 D D 22 Under-ceiling board, wood fibre insulation panel 0.05 250 E E 240 Wood fibre insulation panel 0.04 110 E F — Sealing sheet — — E G 100 CLT BBS, 5-layered 0.12 450 D H 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D I 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 J 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 56.45 cm 149.96 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 993 -67.6 0.277

ROOF 6 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.130 Sound insulation Rw [dB] 52  Ecology ∆OI3 96 A B D E F C G Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Concrete roofing tiles — 2,100 A1 B 30 Wooden battens (30/50) 0.13 475 D C 50 Wooden counter battens (min 50 mm) 0.13 475 D D — Sheathing membrane (laminated; sd ≤ 0.12 m) — — E E 220 Mineral wool above-rafter insulation system, e.g. Isover Integra Basic 0.034 110 A1 F — Sealing sheet — — E G 100 CLT BBS, 5-layered 0.12 450 D Total 45 cm 128.48 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 967 4.87 0.471 Steep roof – solid timber construction, visual surface quality, rear ventilated: DA02 k

ROOF 7 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.109 Sound insulation Rw [dB] 59  Ecology ∆OI3 101 A B D E C G F H I J Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Concrete roofing tiles — 2,100 A1 B 30 Wooden battens (30/50) 0.13 475 D C 50 Wooden counter battens (min 50 mm) 0.13 475 D D — Sheathing membrane (laminated; sd ≤ 0.12 m) — — E E 220 Mineral wool above-rafter insulation system, e.g. Isover Integra Basic 0.034 110 A1 F — Sealing sheet — — E G 100 CLT BBS, 5-layered 0.12 450 D H 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D I 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 J 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 52.25 cm 142.26 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,053 4.64 0.492 Steel roof – solid timber construction, rear ventilated: DA02 l

ROOF 8 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.130 Sound insulation Rw [dB] 45  Ecology ∆OI3 123 A B D E C F G Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 20 Profiled sheeting — 7,800 A1 B 30 Wooden battens (30/50) 0.13 475 D C 80 Wooden counter battens 0.13 475 D D — Sheathing membrane (laminated; sd ≤ 0.12 m) — — E E 220 Mineral wool above-rafter insulation system, e.g. Isover Integra Basic 0.034 110 A1 F — Sealing sheet — — E G 100 CLT BBS, 5-layered 0.12 450 D Total 45 cm 86.66 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,265 18.3 0.584 Steep roof – solid timber construction, visual surface quality, rear ventilated: DA04 k

ROOF 9 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.109 Sound insulation Rw [dB] 52  Ecology ∆OI3 129 A B D E C F G H I J Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 20 Profiled sheeting — 7,800 A1 B 30 Wooden battens (30/50) 0.13 475 D C 80 Wooden counter battens 0.13 475 D D — Sheathing membrane (laminated; sd ≤ 0.12 m) — — E E 220 Mineral wool above-rafter insulation system, e.g. Isover Integra Basic 0.034 110 A1 F — Sealing sheet — — E G 100 CLT BBS, 5-layered 0.12 450 D H 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D I 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 J 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 52.25 cm 100.44 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,348 18.4 0.604 Steel roof – solid timber construction, rear ventilated: DA04 l

ROOF 10 Roof – solid timber construction, rear ventilated: DA05 a A B D C E Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.138 Sound insulation Rw [dB] 39  Ecology ∆OI3 65 Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Expanded polystyrol (pitch insulation) 0.032 30 E C 100 Expanded polystyrol 0.038 30 E D — Sealing sheet (sd ≥ 220 m) — — E E 100 CLT BBS, 5-layered 0.12 450 D Total 32.25 cm 53.30 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,159 -17 0.220 Flat roof – solid timber construction, visual quality: DA05 a

ROOF 11 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Roof – solid timber construction, rear ventilated: DA05 c Building physical and ecological rating Fire protection REI i  o 90 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.114 Sound insulation Rw [dB] 43  Ecology ∆OI3 73 A C B D G E F H Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Expanded polystyrol (pitch insulation) 0.032 30 E C 100 Expanded polystyrol 0.038 30 E D — Sealing sheet (sd ≥ 220 m) — — E E 100 CLT BBS, 5-layered 0.12 450 D F 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D G 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 H 30 Rigips RF fire protection board* (2 x 15 mm) 0.25 800 A2 Total 41.25 cm 81.09 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,294 -15.1 0.246 Flat roof – solid timber construction, suspended: DA05 c

ROOF 12 Roof – solid timber construction, rear ventilated: DA05 a Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.115 Sound insulation Rw [dB] 43  Ecology ∆OI3 71 A B D C E F G H Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Expanded polystyrol (pitch insulation) 0.032 30 E C 100 Expanded polystyrol 0.038 30 E D — Sealing sheet (sd ≥ 220 m) — — E E 100 CLT BBS, 5-layered 0.12 450 D F 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D G 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 H 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 39.50 cm 67.09 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,245 -17.2 0.241 Flat roof – solid timber construction, suspended: DA05 f

ROOF 13 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Roof – solid timber construction, rear ventilated: DA05 c Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.137 Sound insulation Rw [dB] 39  Ecology ∆OI3 67 A B D C E F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Expanded polystyrol (pitch insulation) 0.032 30 E C 100 Expanded polystyrol 0.038 30 E D — Sealing sheet (sd ≥ 220 m) — — E E 100 CLT BBS, 5-layered 0.12 450 D F 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 33.50 cm 63.30 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,194 -15.4 0.223 Flat roof – solid timber construction: DA05 g

ROOF 14 Roof – solid timber construction, rear ventilated: DA05 a Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.136 Sound insulation Rw [dB] 55  Ecology ∆OI3 85 A B D C E F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Expanded polystyrol (pitch insulation) 0.032 30 E D 100 Expanded polystyrol 0.038 30 E E — Sealing sheet (sd ≥ 220 m) — — E F 100 CLT BBS, 5-layered 0.12 450 D Total 37.25 cm 128.30 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,356 9.61 0.283 Flat roof – solid timber construction, visual quality: DA06 a

ROOF 15 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Roof – solid timber construction, rear ventilated: DA05 c Building physical and ecological rating Fire protection REI i  o 90 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.113 Sound insulation Rw [dB] 61  Ecology ∆OI3 93 A B D C E H F G I Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Expanded polystyrol (pitch insulation) 0.032 30 E D 100 Expanded polystyrol 0.038 30 E E — Sealing sheet (sd ≥ 220 m) — — E F 100 CLT BBS, 5-layered 0.12 450 D G 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D H 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 I 30 Rigips RF fire protection board* (2 x 15 mm) 0.25 800 A2 Total 46.25 cm 156.09 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,490 11.6 0.310 Flat roof – solid timber construction, suspended: DA06 c

ROOF 16 Roof – solid timber construction, rear ventilated: DA05 a Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.114 Sound insulation Rw [dB] 61  Ecology ∆OI3 90 A B D C E H F G I Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Expanded polystyrol (pitch insulation) 0.032 30 E D 100 Expanded polystyrol 0.038 30 E E — Sealing sheet (sd ≥ 220 m) — — E F 100 CLT BBS, 5-layered 0.12 450 D G 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D H 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 I 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 44.50 cm 142.09 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,441 9.39 0.304 Flat roof – solid timber construction, suspended: DA06 f

ROOF 17 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Roof – solid timber construction, rear ventilated: DA05 c Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.135 Sound insulation Rw [dB] 55  Ecology ∆OI3 87 A B D G C E F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Expanded polystyrol (pitch insulation) 0.032 30 E D 100 Expanded polystyrol 0.038 30 E E — Sealing sheet (sd ≥ 220 m) — — E F 100 CLT BBS, 5-layered 0.12 450 D G 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 38.50 cm 138.30 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,391 11.2 0.287 Flat roof – solid timber construction: DA06 g

ROOF 18 Roof – solid timber construction, rear ventilated: DA05 a Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 5 m; max. load (q fi, d ) = 5.50 [kN/m²] Heat insulation U [W/m²K] 0.135 Sound insulation Rw [dB] 39  Ecology ∆OI3 68 A B D C E Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Expanded polystyrol (pitch insulation) 0.032 30 E C 100 Expanded polystyrol 0.038 30 E D — Sealing sheet (sd ≥ 220 m) — — E E 120 CLT BBS, 5-layered 0.12 450 D Total 34.25 cm 62.30 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,227 -26.9 0.240 Flat roof – solid timber construction, visual quality: DA07 a

ROOF 19 Roof – solid timber construction, rear ventilated: DA05 c Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 5 m; max. load (q fi, d ) = 5.50 [kN/m²] Heat insulation U [W/m²K] 0.133 Sound insulation Rw [dB] 55  Ecology ∆OI3 88 A B D C E F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Expanded polystyrol (pitch insulation) 0.032 30 E D 100 Expanded polystyrol 0.038 30 E E — Sealing sheet (sd ≥ 220 m) — — E F 120 CLT BBS, 5-layered 0.12 450 D Total 39.25 cm 137.30 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,423 -0.316 0.304 Flat roof – solid timber construction, visual quality: DA08 a

ROOF 20 Roof – solid timber construction, rear ventilated: DA05 a Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.151 Sound insulation Rw [dB] 48  Ecology ∆OI3 122 A B D C E Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 C 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D — Sealing sheet (sd ≥ 220 m) — — E E 100 CLT BBS, 5-layered 0.12 450 D Total 32.25 cm 79.70 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,212 19.3 0.587 Flat roof – solid timber construction, visual quality: DA09 a

ROOF 21 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Roof – solid timber construction, rear ventilated: DA05 c Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.150 Sound insulation Rw [dB] 48  Ecology ∆OI3 124 A B D C E F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 C 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D — Sealing sheet (sd ≥ 220 m) — — E E 100 CLT BBS, 5-layered 0.12 450 D F 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 33.50 cm 89.70 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,247 20.9 0.591 Flat roof – solid timber construction: DA09 b

ROOF 22 Roof – solid timber construction, rear ventilated: DA05 a Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.124 Sound insulation Rw [dB] 54  Ecology ∆OI3 128 A B D C E F G H Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 C 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D — Sealing sheet (sd ≥ 220 m) — — E E 100 CLT BBS, 5-layered 0.12 450 D F 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D G 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 H 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 39.50 cm 93.49 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,297 19.1 0.608 Flat roof – solid timber construction, suspended: DA09 c

ROOF 23 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Roof – solid timber construction, rear ventilated: DA05 c Building physical and ecological rating Fire protection REI i  o 90 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.123 Sound insulation Rw [dB] 54  Ecology ∆OI3 130 A B D C E F G H Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 C 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D — Sealing sheet (sd ≥ 220 m) — — E E 100 CLT BBS, 5-layered 0.12 450 D F 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D G 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 H 30 Rigips RF fire protection board* (2 x 15 mm) 0.25 800 A2 Total 41.25 cm 107.49 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,346 21.3 0.614 Flat roof – solid timber construction, suspended: DA09 d

ROOF 24 Roof – solid timber construction, rear ventilated: DA05 a Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.149 Sound insulation Rw [dB] 56  Ecology ∆OI3 141 A B D C E F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 E — Sealing sheet (sd ≥ 220 m) — — E F 100 CLT BBS, 5-layered 0.12 450 D Total 37.25 cm 154.70 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,408 45.9 0.651 Flat roof – solid timber construction, visual quality: DA10 a

ROOF 25 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Roof – solid timber construction, rear ventilated: DA05 c Building physical and ecological rating Fire protection REI i  o 30 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.148 Sound insulation Rw [dB] 56  Ecology ∆OI3 143 A B D C E F G Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 E — Sealing sheet (sd ≥ 220 m) — — E F 100 CLT BBS, 5-layered 0.12 450 D G 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 38.50 cm 164.70 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,443 47.5 0.655 Flat roof – solid timber construction: DA10 b

ROOF 26 Roof – solid timber construction, rear ventilated: DA05 a Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.123 Sound insulation Rw [dB] 62  Ecology ∆OI3 147 A B D C E H F G I Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 E — Sealing sheet (sd ≥ 220 m) — — E F 100 CLT BBS, 5-layered 0.12 450 D G 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D H 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 I 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 44.50 cm 168.49 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,494 45.7 0.672 Flat roof – solid timber construction, suspended: DA1 c

ROOF 27 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Roof – solid timber construction, rear ventilated: DA05 c Building physical and ecological rating Fire protection REI i  o 90 max. width l = 4 m; max. load (q fi, d ) = 6.95 [kN/m²] Heat insulation U [W/m²K] 0.121 Sound insulation Rw [dB] 62  Ecology ∆OI3 150 A B D C E H F G I Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 50 Gravel 0.7 1,500 A1 B 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E C 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 E — Sealing sheet (sd ≥ 220 m) — — E F 100 CLT BBS, 5-layered 0.12 450 D G 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D H 50 Mineral wool, e.g. Isover ULTIMATE UKF-034 twin 0.034 21 A1 I 30 Rigips RF fire protection board* (2 x 15 mm) 0.25 800 A2 Total 46.25 cm 182.49 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,542 47.9 0.678 Flat roof – solid timber construction, suspended: DA1 d

ROOF 28 Roof – solid timber construction, rear ventilated: DA05 a Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating Fire protection REI i  o 60 max. width l = 5 m; max. load (q fi, d ) = 5.50 [kN/m²] Heat insulation U [W/m²K] 0.147 Sound insulation Rw [dB] 48  Ecology ∆OI3 125 A B D C E Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W/ (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 2.5 Fabric-reinforced plastic welded sheeting (> 1.7 kg/m²) — 680 E B 120 Mineral wool flat roof insulation (pitch insulation), e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 C 100 Mineral wool flat roof insulation, e.g. Isover Metac FLP 1 Duratec 0.039 150 A1 D — Sealing sheet (sd ≥ 220 m) — — E E 120 CLT BBS, 5-layered 0.12 450 D Total 34.25 cm 88.70 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,279 9.39 0.608 Flat roof – solid timber construction, visual quality: DA11 a

RkJQdWJsaXNoZXIy NTQ5ODU5