Interior & Partition Wall

INTERIOR & PARTITION WALL SOLID TIMBER MANUAL 2.0

INTERIOR & PARTITION WALL © Binderholz GmbH & Saint-Gobain Rigips Austria GesmbH 1st edition, May 2019 All information in this document reflects the latest state of development and has been prepared for you according to the best of knowledge and good faith. As we always strive to offer the best possible solutions for you, changes are reserved due to improvements in terms of application or production technology. Ensure yourself that you have the most recent edition of this document available. Printing errors cannot be ruled out. This publication is targeted at trained specialists. Any illustrations of executing activities contained in it are not understood to be any processing instructions, unless expressly marked as such. Renderings and sectional views of the individual assemblies are not depicted on scale; they serve merely as illustration. Our products and systems are aligned to each other. Their interaction has been confirmed by internal and external testing. All information is generally based on the exclusive use of our products. Unless described otherwise, the information does not permit any conclusions as to the combinability with third-party systems or exchangeability of individual parts by external products; to this end, no warranty or liability can be extended. Please also note that our business relationships are exclusively subject to our general terms of sale, delivery and payment (GTC) in the current version. You can receive our GTC on request or find them online at www.binderholz.com and www.rigips.com. We are looking forward to a good cooperation and wish you great success with all of our system solutions. Publisher Binderholz GmbH and Saint-Gobain Rigips Austria GesmbH Technical implementation Dipl.-Ing. (FH) Tim Sleik, Dipl.-Ing. Christian Kolbitsch and Dipl.-Ing. (FH) Jens Koch Graphic implementation Advertising Agency Goldfeder − Jasmin Brunner HOTLINES: Binderholz Bausysteme GmbH Saint-Gobain Rigips Austria GesmbH Tel. +43 6245 70500 Tel. +43 1 616 29 80-517 www.binderholz.com www.rigips.com

CONTENTS    Designation Fire resistance REI Thickness [cm] Sound insulation [dB] Heat insulation [W/m²K] Page IW01 b interior wall 30 9.00 33 0.990 4 IW01 c interior wall 60 10.00 33 0.915 5 IW02 c interior wall 90 13.00 38 0.824 6 IW02 d interior wall 60 11.50 38 0.901 7 IW03 c interior wall 60 | 60 18.25 51 0.393 8 IW04 b interior wall 60 | 90 21.00 62 0.322 9 IW04 c interior wall 30 | 60 20.00 62 0.331 10 IW04 d interior wall 60 | 60 19.75 57 0.327 11 IW05c interior wall 90 29.00 69 0.248 12 IW06 b interior wall 90 32.00 68 0.195 13 IW06 c interior wall 60 31.00 68 0.198 14 IW07 interior wall 60 | 60 13.95 46 0.523 15 IW08 a interior wall 30 | 60 16.25 45 0.410 16 IW08 b interior wall 60 | 60 17.25 45 0.396 17 IW08 c interior wall 60 | 60 17.50 45 0.402 18 IW08 d interior wall 90 | 90 19.00 45 0.386 19 IW09 a interior wall 60 23.50 50 0.261 20 IW09 b interior wall 90 25.00 50 0.253 21 IW10 b partition wall 60 26.00 52 0.283 22 IW11 b partition wall 90 29.00 58 0.280 23 IW12 b partition wall 90 | 90 36.25 65 0.198 24 IW13 c partition wall 90 | 90 37.75 65 0.180 25 IW14 b partition wall 60 | 90 27.50 58 0.281 26 IW15 b partition wall 60 | 60 34.50 70 0.201 27 IW18 b partition wall 60 | 90 28.75 58 0.277 28 IW19 b partition wall 60 | 60 33.25 67 0.203 29 INTERIOR & PARTITION WALL

INTERIOR & PARTITION WALL 4 A Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 30 max. unsupported length l = 3 m; max. load (q fi, d ) = 14.95 [kN/m] Heat insulation U [W/m²K] 0.990  Sound insulation Rw [dB] 33  Ecology ∆OI3 15 Interior wall – solid timber construction, visual surface quality: IW01 b Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 90 CLT BBS, 3-layered 0.12 450 D Total 9 cm 40.50 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 302 -44.7 0.0917

INTERIOR & PARTITION WALL 5 A Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 60 [kN/m] Heat insulation U [W/m²K] 0.915  Sound insulation Rw [dB] 33  Ecology ∆OI3 16 Interior wall – solid timber construction, visual surface quality: IW01 c Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D Total 10 cm 45 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 336 -49.7 0.102

INTERIOR & PARTITION WALL 6 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 90 max. unsupported length l = 3 m; max. load (q fi, d ) = 80 [kN/m] Heat insulation U [W/m²K] 0.824  Sound insulation Rw [dB] 38  Ecology ∆OI3 21 A B C Interior wall – solid timber construction: IW02 c Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 15 Rigips RF fire protection board* 0.25 800 A2 B 100 CLT BBS, 5-layered 0.12 450 D C 15 Rigips RF fire protection board* 0.25 800 A2 Total 13 cm 69 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 420 -45.9 0.111

INTERIOR & PARTITION WALL 7 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 80 [kN/m] Heat insulation U [W/m²K] 0.901  Sound insulation Rw [dB] 38  Ecology ∆OI3 19 B A C Interior wall – solid timber construction: IW02 d Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 12.5 Rigips RF fire protection board* 0.25 800 A2 B 90 CLT BBS, 3-layered 0.12 450 D C 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 11.50 cm 60.50 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 372 -41.6 0.0994

INTERIOR & PARTITION WALL 8 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 60 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 60 [kN/m] max. load (q fi, d ) = layer D 80 [kN/m] Heat insulation U [W/m²K] 0.393  Sound insulation Rw [dB] 51  Ecology ∆OI3 23 B A C D Interior wall – solid timber construction with installation level, visual surface quality: IW03 c Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 70 Wooden battens (60/60; e = 625) on Rigips adjustment vibration mounts 0.13 475 D C 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 18.25 cm 58.94 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 429 -50.2 0.125

INTERIOR & PARTITION WALL 9 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 90 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 60 [kN/m] max. load (q fi, d ) = layer D 80 [kN/m] Heat insulation U [W/m²K] 0.322  Sound insulation Rw [dB] 62  Ecology ∆OI3 39 B A C D Interior wall – solid timber construction with installation level, visual surface quality: IW04 b Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 85 Free-standing facing formwork (Rigips Rigiprofil CW 75) — — A1 C 60 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 Total 21 cm 68.84 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 615 -33.3 0.180

INTERIOR & PARTITION WALL 10 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 30 | 60 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 14.95 [kN/m] max. load (q fi, d ) = layer D 80 [kN/m] Heat insulation U [W/m²K] 0.331  Sound insulation Rw [dB] 62  Ecology ∆OI3 37 B A C D Interior wall – solid timber construction with installation level, visual surface quality: IW04 c Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 90 CLT BBS, 3-layered 0.12 450 D B 85 Free-standing facing formwork (Rigips Rigiprofil CW 75) — — A1 C 60 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 Total 20 cm 64.34 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 581 -28.3 0.170

INTERIOR & PARTITION WALL 11 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 60 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 60 [kN/m] max. load (q fi, d ) = layer D 80 [kN/m] Heat insulation U [W/m²K] 0.327  Sound insulation Rw [dB] 57  Ecology ∆OI3 37 B A C D Interior wall – solid timber construction with installation level, visual surface quality: IW04 d Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 85 Free-standing facing formwork (Rigips Rigiprofil CW 75) — — A1 C 60 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 19.75 cm 58.84 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 580 -34.8 0.176

INTERIOR & PARTITION WALL 12 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 90 max. unsupported length l = 3 m; max. load (q fi, d ) = 54 [kN/m] Heat insulation U [W/m²K] 0.248  Sound insulation Rw [dB] 69  Ecology ∆OI3 33 B C D G F E A Interior wall – solid timber construction with installation level: IW05 c Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 30 Rigips RF fire protection board* (2 x 15 mm) 0.25 800 A2 B 70 Wooden battens (60/60; e = 625) on Rigips adjustment vibration mounts 0.13 475 D C 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 90 CLT BBS, 3-layered 0.12 450 D E 70 Wooden battens (60/60; e = 625) on Rigips adjustment vibration mounts 0.13 475 D F 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 G 30 Rigips RF fire protection board* (2 x 15 mm) 0.25 800 A2 Total 29 cm 96.37 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 586 -41.5 0.150

INTERIOR & PARTITION WALL 13 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 90 max. unsupported length l = 3 m; max. load (q fi, d ) = 80 [kN/m] Heat insulation U [W/m²K] 0.195  Sound insulation Rw [dB] 68  Ecology ∆OI3 61 G F E B C D A Interior wall – solid timber construction with installation level: IW06 b Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 B 85 Free-standing facing formwork (Rigips Rigiprofil CW 75) — — A1 C 60 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 100 CLT BBS, 5-layered 0.12 450 D E 85 Free-standing facing formwork (Rigips Rigiprofil CW 75) — — A1 F 60 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 G 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 Total 32 cm 92.68 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 894 -16.9 0.258

INTERIOR & PARTITION WALL 14 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 80 [kN/m] Heat insulation U [W/m²K] 0.198  Sound insulation Rw [dB] 68  Ecology ∆OI3 60 G F E B C D A Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 B 85 Free-standing facing formwork (Rigips Rigiprofil CW 75) — — A1 C 60 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 90 CLT BBS, 3-layered 0.12 450 D E 85 Free-standing facing formwork (Rigips Rigiprofil CW 75) — — A1 F 60 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 G 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 Total 31 cm 88.18 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 860 -11.9 0.248 Interior wall – solid timber construction with installation level: IW06 c

INTERIOR & PARTITION WALL 15 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 60 [kN/m] Heat insulation U [W/m²K] 0.523  Sound insulation Rw [dB] 46  Ecology ∆OI3 47 B A C D Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 27 Rigips spring rail (e = 625) — — A1 C 27 Mineral wool 40 mm compressed in the panel, e.g. Isover Akustic SSP1 0.039 25 A1 D 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 13.95 cm 57.10 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 690 -26.8 0.214 Interior wall – solid timber construction with installation level, visual surface quality: IW07

INTERIOR & PARTITION WALL 16 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 30 | 60 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 14.95 [kN/m] max. load (q fi, d ) = layer D 14.95 [kN/m] Heat insulation U [W/m²K] 0.410  Sound insulation Rw [dB] 45  Ecology ∆OI3 21 B A C D Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 90 CLT BBS 3-layered 0.12 450 D B 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D C 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 16.25 cm 54.44 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 394 -44.6 0.115 Interior wall – solid timber construction with installation level, visual surface quality: IW08 a

INTERIOR & PARTITION WALL 17 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 60 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 60 [kN/m] max. load (q fi, d ) = layer D 80 [kN/m] Heat insulation U [W/m²K] 0.396  Sound insulation Rw [dB] 45  Ecology ∆OI3 23 B A C D Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D C 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 17.25 cm 58.94 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 428 -49.5 0.125 Interior wall – solid timber construction with installation level, visual surface quality: IW08 b

INTERIOR & PARTITION WALL 18 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 60 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 80 [kN/m] max. load (q fi, d ) = layer E 80 [kN/m] Heat insulation U [W/m²K] 0.402  Sound insulation Rw [dB] 45  Ecology ∆OI3 23 C B D E A Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 12.5 Rigips RF fire protection board* 0.25 800 A2 B 90 CLT BBS, 3-layered 0.12 450 D C 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D D 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 E 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 17.50 cm 64.44 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 429 -43 0.119 Interior wall – solid timber construction with installation level: IW08 c

INTERIOR & PARTITION WALL 19 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 90 | 90 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 80 [kN/m] max. load (q fi, d ) = layer E 80 [kN/m] Heat insulation U [W/m²K] 0.386  Sound insulation Rw [dB] 45  Ecology ∆OI3 25 C B D E A Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 15 Rigips RF fire protection board* 0.25 800 A2 B 100 CLT BBS, 5-layered 0.12 450 D C 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D D 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 E 15 Rigips RF fire protection board* 0.25 800 A2 Total 19 cm 72.94 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 477 -47.4 0.130 Interior wall – solid timber construction with installation level: IW08 d

INTERIOR & PARTITION WALL 20 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 80 [kN/m] Heat insulation U [W/m²K] 0.261  Sound insulation Rw [dB] 50  Ecology ∆OI3 27 G E F B C D A Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 12.5 Rigips RF fire protection board* 0.25 800 A2 B 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D C 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 90 CLT BBS, 3-layered 0.12 450 D E 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D F 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 G 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 23.50 cm 68.37 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 486 -44.5 0.138 Interior wall – solid timber construction with installation level: IW09 a

INTERIOR & PARTITION WALL 21 Inspection by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 90 max. unsupported length l = 3 m; max. load (q fi, d ) = 80 [kN/m] Heat insulation U [W/m²K] 0.253  Sound insulation Rw [dB] 50  Ecology ∆OI3 30 G E F B C D A Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 15 Rigips RF fire protection board* 0.25 800 A2 B 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D C 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 100 CLT BBS, 5-layered 0.12 450 D E 60 Wooden battens (60/60; e = 625) directly bolted on 0.13 475 D F 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 G 15 Rigips RF fire protection board* 0.25 800 A2 Total 25 cm 76.87 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 534 -48.8 0.150 Interior wall – solid timber construction with installation level: IW09 b

INTERIOR & PARTITION WALL 22 Classification by IBS – Institut für Brandschutztechnik und Sicherheitsforschung [Institute for Fire Protection Technology and Safety Research], A-4020 Linz Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 max. unsupported length l = 3 m; max. load (q fi, d ) = 60 [kN/m] Heat insulation U [W/m²K] 0.283  Sound insulation Rw [dB] 52  Ecology ∆OI3 38 A B C D Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 C 10 Air space 0 — — D 100 CLT BBS, 5-layered 0.12 450 D Total 26 cm 91.20 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 727 -96.4 0.222 Partition wall – solid timber construction, visual surface quality: IW10 b

INTERIOR & PARTITION WALL 23 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 90 max. unsupported length l = 3 m; max. load (q fi, d ) = 12 [kN/m] Heat insulation U [W/m²K] 0.280  Sound insulation Rw [dB] 58  Ecology ∆OI3 42 A B C D E F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 B 90 CLT BBS, 3-layered 0.12 450 D C 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 10 Air space 0 — — E 90 CLT BBS, 3-layered 0.12 450 D F 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 Total 29 cm 122.20 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 800 -80.2 0.217 Partition wall – solid timber construction: IW11 b

INTERIOR & PARTITION WALL 24 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 90 | 90 max. unsupported length l = 3 m max. load (q fi, d ) layer A = 18.7 [kN/m] max. load (q fi, d ) layer H = 54 [kN/m] Heat insulation U [W/m²K] 0.198  Sound insulation Rw [dB] 65  Ecology ∆OI3 47 A B C D E F G H Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 12.5 Rigips RF fire protection board* 0.25 800 A2 B 100 CLT BBS, 5-layered 0.12 450 D C 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 10 Air space 0 — — E 90 CLT BBS, 3-layered 0.12 450 D F 70 Wooden battens (60/60; e = 625) on Rigips adjustment vibration mounts 0.13 475 D G 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 H 30 Rigips RF fire protection board* (2 x 15 mm) 0.25 800 A2 Total 36.25 cm 124.64 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 870 -88.3 0.245 Partition wall – solid timber construction with installation level: IW12 b

INTERIOR & PARTITION WALL 25 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 90 | 90 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 18.7 [kN/m] max. load (q fi, d ) = layer H 54 [kN/m] Heat insulation U [W/m²K] 0.180  Sound insulation Rw [dB] 65  Ecology ∆OI3 61 A B C D E F H G Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 12.5 Rigips RF fire protection board* 0.25 800 A2 B 100 CLT BBS, 5-layered 0.12 450 D C 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 10 Air space 0 — — E 90 CLT BBS, 3-layered 0.12 450 D F 85 Free-standing facing formwork (Rigips Rigiprofil CW 75) — — A1 G 60 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 H 30 Rigips RF fire protection board* (2 x 15 mm) 0.25 800 A2 Total 37.75 cm 124.54 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 1,021 -72.9 0.296 Partition wall – solid timber construction with installation level: IW13 c

INTERIOR & PARTITION WALL 26 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 90 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 14.95 [kN/m] max. load (q fi, d ) = layer F 18.70 [kN/m] Heat insulation U [W/m²K] 0.281  Sound insulation Rw [dB] 58  Ecology ∆OI3 40 A B C D E F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 12.5 Rigips RF fire protection board* 0.25 800 A2 B 90 CLT BBS, 3-layered 0.12 450 D C 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 10 Air space 0 — — E 100 CLT BBS, 5-layered 0.12 450 D F 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 27.50 cm 106.70 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 763 -88.3 0.220 Partition wall – solid timber construction: IW14

INTERIOR & PARTITION WALL 27 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 60 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 60 [kN/m] max. load (q fi, d ) = layer G 80 [kN/m] Heat insulation U [W/m²K] 0.201  Sound insulation Rw [dB] 70  Ecology ∆OI3 44 A B C D E G F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 C 10 Air space 0 — — D 90 CLT BBS, 3-layered 0.12 450 D E 70 Wooden battens (60/60; e = 625) on Rigips adjustment vibration mounts 0.13 475 D F 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 G 25 Rigips RF fire protection board* (2 x 12.5 mm) 0.25 800 A2 Total 34.50 cm 110.64 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 822 -90.4 0.239 Partition wall – solid timber construction with installation level, visual surface quality: IW15

INTERIOR & PARTITION WALL 28 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 90 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 80 [kN/m] max. load (q fi, d ) = layer G 18.7 [kN/m] Heat insulation U [W/m²K] 0.277  Sound insulation Rw [dB] 58  Ecology ∆OI3 42 A B C D E F G Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 12.5 Rigips RF fire protection board* 0.25 800 A2 B 90 CLT BBS, 3-layered 0.12 450 D C 12.5 Rigips RF fire protection board* 0.25 800 A2 D 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 E 10 Air space 0 — — F 100 CLT BBS, 5-layered 0.12 450 D G 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 28.75 cm 116.70 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 798 -86.7 0.224 Partition wall – solid timber construction: IW18

INTERIOR & PARTITION WALL 29 Rating by MFPA Leipzig – Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen [Society for Material Research and Testing Institute for the Construction Industry], D-04319 Leipzig Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna Rated by ift Rosenheim – Schallschutzzentrum [Sound Insulation Centre], D-83026 Rosenheim and respectively Holzforschung Austria, A-1030 Vienna Calculation by IBO – Österreichisches Institut für Bauen und Ökologie [Austrian Institute for Construction and Ecology], A-1090 Vienna *Equal fire resistance and sound insulation when using Rigidur H gypsum fibre boards or Riduro wooden building slabs. The assemblies shown were rated by accredited testing institutes on behalf of binderholz and Saint-Gobain Rigips Austria. Building physical and ecological rating  Fire protection REI 60 | 60 max. unsupported length l = 3 m max. load (q fi, d ) = layer A 60 [kN/m] max. load (q fi, d ) = layer G 80 [kN/m] Heat insulation U [W/m²K] 0.203  Sound insulation Rw [dB] 67  Ecology ∆OI3 42 A B C D E G F Building material specifications for construction, layer structure | from the inside to the outside Thickness [mm] Building material Heat conductivity  [W / (m · K)] Gross density  [kg / m³] Flammability class EN 13501-1 A 100 CLT BBS, 5-layered 0.12 450 D B 10 Air space 0 — — C 50 Mineral wool secured in position, e.g. Isover Kontur KP 1-035 0.034 24 A1 D 90 CLT BBS, 3-layered 0.12 450 D E 70 Wooden battens (60/60; e = 625) on Rigips adjustment vibration mounts 0.13 475 D F 50 Mineral wool, e.g. Isover Kontur KP 1-035 0.034 24 A1 G 12.5 Rigips RF fire protection board* 0.25 800 A2 Total 33.25 cm 100.64 kg/m² Ecological rating in detail | www.baubook.info/massivholzhandbuch PENRT [MJ/m²] GWP100 total [kg CO2/m²] AP [kg SO2/m²] 787 -92 0.235 Partition wall – solid timber construction with installation level, visual surface quality: IW19

RkJQdWJsaXNoZXIy NTQ5ODU5